系列型號(hào):
HRTH-Y-2H2D-X-T跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-Y-2Z-X-T跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-Y-2H-X-T跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-J-2H2D-X-T跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-J-2Z-X-T跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-J -2H-X-T跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-Y-2H2D跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-Y-2Z跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-Y-2H跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-J-2H2D跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-J-2Z跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-J -2H跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-2Z跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-2H2D跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-2Z-X-T跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
HRTH-J-2H2D-X跳位監(jiān)視、合位監(jiān)視、電源監(jiān)控繼電器;
1、使用條件
A.不得有雨水和雪,有防霧、防塵、防風(fēng)沙設(shè)施。
B.周?chē)艌?chǎng)強(qiáng)度:小于0.5mT;
C.工作位置:任意;
D.工作電壓:不大于120%額定電壓;
E).無(wú)導(dǎo)電氣體,無(wú)腐蝕性氣體,無(wú)較強(qiáng)振動(dòng);
F.環(huán)境溫度:-10℃~50℃;
2、用途
HRTH系列繼電器用于直流或交流操作的各種自動(dòng)控制或保護(hù)線路中,可以直接控制分閘、合閘回路,監(jiān)視控制電源,并方便調(diào)節(jié)合閘回路 和電源監(jiān)視回路出口中間繼電器斷電返回的延時(shí)時(shí)間。
3、HRTH-J-2H2D-X-T/DF電源監(jiān)視繼電器 220VAC 0.1~3S技術(shù)參數(shù)
(1).額定值:220VDC、110VDC、48VDC、380VAC、220VAC、110VAC。
(2).動(dòng)作值:直流電壓不大于70%額定值,交流電壓不大于80%額定值。
(3).返回值:不小于10%額定值。
(4).動(dòng)作時(shí)間:施加額定電壓,動(dòng)作時(shí)間小于20ms。
(5).返回時(shí)間:分閘回路小于20ms,合閘回路20ms~3s可調(diào),電源監(jiān)視回路20ms~3s可調(diào)。
(6).功 耗:整體功耗小于10W。
(7).觸點(diǎn)容量:可長(zhǎng)期接通5A,在250VDC τ=5ms條件,大可斷開(kāi)50W直流有感負(fù)載;
在250VAC COSΦ=0.4大可斷開(kāi)250VA交流負(fù)載。
(8).絕緣電阻:外殼與外露帶電端子之間,用開(kāi)路電壓500V的兆歐表測(cè)量,絕緣電阻大于300MΩ。
(9).介質(zhì)強(qiáng)度:外殼與外露帶電端子之間,能承受2KV(有效值)50Hz試驗(yàn)電壓,歷時(shí)1分鐘不擊穿,無(wú)閃絡(luò)。
4、端子接線圖
5、外形尺寸
HRTH-J-2H2D-X-T/DF電源監(jiān)視繼電器 220VAC 0.1~3S
所有評(píng)論僅代表網(wǎng)友意見(jiàn),與本站立場(chǎng)無(wú)關(guān)。