Natural gas ATEX, cUL approved PPM Oxygen Transmitter, 0-10 PPM low range, measures O2 concentrations from 0.01 PPM to 1%. The GPR-1500 AIS features certification to ATEX Directive 94/9/EC and cUL designed exclusively for Natural Gas applications. This analyzer features an advanced galvanic trace PPM oxygen sensor, a 18 month operating sensor operating life, menu driven controls, two (2) field selectable alarm set points. Pictured with optional A-3393 modular sample system designed to remove moderate amounts of free liquids and H2S from natural gas streams.
Certifications:
ULc Class I Div I Group C, D
ATEX Directive 94/9/ II 2G
Ex d [ib] ib IIB T4 Gb
Tamb -10oC to 50oC
Accuracy: | < 2% of FS range under constant conditions | Analysis Ranges: | 0-10 PPM, 0-100 PPM, 0-1000 PPM, 0-1%, 0-25% FS ranges; |
Application: | Oxygen analysis in inert, hydrocarbon, hydrogen, mixed and acid (CO2) gas streams | Approvals: | ATEX Directive 94/9/EC II 2 G Ex d [ib] ib IIB T4 Gb Tamb -20?C to +50?C |
Area Classification: | cUL for Class 1, Division 1, Group C, D hazardous | Alarms: | Two user configurable alarms: relays rated 3A at 100 VAC, alarm time delays, alarm bypass, power/system fail alarm |
Calibration: | Air or certified span gas of O2 balance N2 | Compensation: | Barometric pressure and temperature |
Connections: | 1/8″ compression tube fittings | Controls: | Menu driven range selection, calibration and system functions |
Display: | Graphical LCD 2.75” x 1.375”; resolution 0.01 PPM; displays real time ambient temperature and pressure | Enclosure: | Aluminum ex-proof, fiberglass Type R3, 16x9x6”, 20 lbs. |
Flow: | 1-5 SCFH, 1-2 SCFH recommended | Linearity: | >0.995 over all ranges |
Pressure: | Inlet – regulate to 5-30 psig to deliver 1-2 SCFH flow to transmitter; vent – atmospheric | Power: | 12-24 VDC or 100/230 VAC (ATEX only) |
Response Time: | 90% of final reading in 10 seconds | Sample System: | Flow control/meter, sample/span valve |
Sensitivity: | < 0.5% of FS range | Sensor Model: | XLT-12-333 for gases containing > 0.5% CO2 |
Sensor Life: | 24 months at 25ºC and 1 atm. | Signal Output: | 4-20 mA non loop current |
Operating Range: | Recommended -10ºto 45ºC | Warranty: | 12 months analyzer; 12 months sensor |
Weted Parts: | Stainless steel | Communication: | Optional Mod-bus communication |