托馳(上海)工業(yè)傳感器有限公司
初級(jí)會(huì)員 | 第1年

13301685667

當(dāng)前位置:托馳(上海)工業(yè)傳感器有限公司>>美國(guó)ADV氧氣分析儀>>美國(guó)ADV氧氣變送器>> GPR-1500GPR-1500 PPM O2 TRANSMITTER氧氣分析儀

GPR-1500 PPM O2 TRANSMITTER氧氣分析儀

參  考  價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)

產(chǎn)品型號(hào)GPR-1500

品       牌

廠(chǎng)商性質(zhì)代理商

所  在  地上海市

更新時(shí)間:2022-05-03 18:00:02瀏覽次數(shù):38次

聯(lián)系我時(shí),請(qǐng)告知來(lái)自 興旺寶
同類(lèi)優(yōu)質(zhì)產(chǎn)品更多>
GPR-1500 PPM O2 TRANSMITTER
ATEX approved Intrinsically safe 2-wire loop powered PPM oxygen transmitter 0-10 PPM low range, for measuring O2 from 0.1 PPM to 1%. The transmitterfeatures

GPR-1500 PPM O2 TRANSMITTER

 

ATEX approved Intrinsically safe 2-wire loop powered PPM oxygen transmitter 0-10 PPM low range, for measuring O2 from 0.1 PPM to 1%. The transmitterfeatures 

  • certification to ATEX Directive 94/9/EC
  • an advanced galvanic trace PPM oxygen sensor
  • 24 month operating sensor life
  • menu driven controls and
  • a stainless steel sample system.

  

Caution: To comply with ATEX Directive 94/9/EC, the user must use recommended safety barrier 

Certification: ATEX II 2B

                            Ex ia IIB T4 Gb

                            Tamb -10oC to 45oC

 

  

*Accuracy:< 2% of FS range under constant conditionsAnalysis Ranges:0-10 PPM, 0-100 PPM, 0-1000 PPM, 0-1%, 0-25% FS ranges;
Application:Oxygen analysis in inert, hydrocarbon, hydrogen, mixed and acid (CO2) gas streamsApprovals:INERIS 08ATEX0036
II 1 G
Ex ia IIB T4
Area Classification:Class 1, Division 1, Group C, D hazardousCalibration:Air or certified span gas of O2 balance N2
Compensation:Barometric pressure and temperatureConnections:1/8″ compression tube fittings
Controls:Menu driven range selection, calibration and system functionsDisplay:Graphical LCD 2.75” x 1.375”; resolution 0.01 PPM
Enclosure:Painted aluminum NEMA 4X, 4”x9”x3″, 8 lbs.Flow Sensitivity:None between 0.5-5 SCFH, 1-2 SCFH recommended
Linearity:±1% of full scalePressure:Inlet – regulate to 5-30 psig, vent – atmospheric
Power:18-24 VDC Loop PowerRecovery Time:60 seconds in air to < 10 PPM in < 1 hour on N2purge
Response Time:90% of final reading in 10 secondsSample System:None
Sensitivity:< 0.5% of FS rangeSensor Model:GPR-12-333 for inert gases;
Sensor Life:18 months at 25ºC and 1 atm.Signal Output:4-20mA Loop Current
Operating Range:-10 ºC to 45ºCWarranty:12 months analyzer; 12 months sensor