上海涸宇機(jī)電科技有限公司
初級會(huì)員 | 第1年

17317611498

當(dāng)前位置:上海涸宇機(jī)電科技有限公司>>實(shí)驗(yàn)室常規(guī)耗材>>美國Hausser細(xì)胞計(jì)數(shù)板>> 4000、4001美國Hausser細(xì)胞計(jì)數(shù)板

美國Hausser細(xì)胞計(jì)數(shù)板

參  考  價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)

產(chǎn)品型號(hào)4000、4001

品       牌

廠商性質(zhì)經(jīng)銷商

所  在  地上海市

更新時(shí)間:2022-05-29 10:30:03瀏覽次數(shù):36次

聯(lián)系我時(shí),請告知來自 興旺寶
同類優(yōu)質(zhì)產(chǎn)品更多>
美國Hausser細(xì)胞計(jì)數(shù)板(Nageotte Counting Chamber):亮線型,常用于單采血小板中的殘留白細(xì)胞的計(jì)數(shù)。池深:0.5mm。提供兩種:一種H型,中間有溝隔開為兩計(jì)數(shù)區(qū)(貨號(hào)4000),一種沒有溝槽(4001)

美國Hausser細(xì)胞計(jì)數(shù)板(Nageotte Counting Chamber):亮線型,常用于單采血小板中的殘留白細(xì)胞的計(jì)數(shù)。池深:0.5mm。提供兩種:一種H型,中間有溝隔開為兩計(jì)數(shù)區(qū)(貨號(hào)4000),一種沒有溝槽(4001)美國Hausser scientific血球計(jì)數(shù)板,霍華德霉菌計(jì)數(shù)板,準(zhǔn)確計(jì)算白細(xì)胞、紅細(xì)胞、血小板、組織培養(yǎng)細(xì)胞、細(xì)菌和精子The Hausser Nageotte Bright-Line Hemacytometer allows one to manually count low leukocyte concentrations below the capabilities of a standard Hemacytometer. The Nageotte contains two gridded counting areas each containing 40 rectangular areas. Total volume of each grid is 50 mL for a total volume of 100 mL per Nageotte. The Nageotte can accuray measure down to 0.1 cell/mL (100 cell/ml). Cell Depth is 0.5mm .

美國Hausser細(xì)胞計(jì)數(shù)板

Available with an H-shaped moat(catalog#4000) that separates the two gridded areas or without a moat (catalog#4001). The Nageotte Chamber comes with two reusable cover slips(30mm X 33mm X 0.5mm) and 1/2 oz (approx. 35 pcs.) of disposable cover slips (30mm X 33mm X 0.15mm). PROCESS: Counting low levels of white cells in white cell-reduced plaetcomponents.BACKGROUND: Determination of the white cell (WBC) count in WBC-reduced plaet components requires methods that have a detection limit in the range of approximay 5.0 x 10(2) to 5.0 x 10(4) per mL.STUDY DESIGN AND METHODS: With a 50-microL Nageotte hemocytometer and bright-field microscopy (200x magnification), studies were conducted to develop and validate a method that could be used routinely with filtered and apheresis-harvested plaets. A 1-in-5 dilution of sample with a commercially available blood-diluting fluid was used because, with a lower (1-in-2) dilution, the observed number of WBCs was substantially less than the number expected at relatively high plaet counts (> 1.9 x 10(9)/mL). RESULTS: The observed and expected WBC counts in WBC-reduced plaet samples correlated well at levels between approximay 5 and 1100 WBCs per counting area (5.0 x 10(2)-1.1 x 10(5)/mL). At levels of more than 300 to 400 WBCs per counting area, accurate counts were obtained when 10 of the 40 rectangles were counted.

會(huì)員登錄

×

請輸入賬號(hào)

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
撥打電話
在線留言