您好,歡迎來到興旺寶!請 |免費(fèi)注冊

產(chǎn)品展廳本站服務(wù)收藏該商鋪

珠??祵毴R儀表有限公司

免費(fèi)會員
手機(jī)逛
珠??祵毴R儀表有限公司
當(dāng)前位置:珠海康寶萊儀表有限公司>>便攜式檢測儀器>>多功能儀表電氣裝置Multifunction Electrical Installations Meter>> MPI-525MPI-525 多功能儀表電氣裝置

MPI-525 多功能儀表電氣裝置

產(chǎn)品二維碼
參  考  價(jià):面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 產(chǎn)品型號:MPI-525
  • 品牌:
  • 產(chǎn)品類別:I/O模塊
  • 所在地:珠海市
  • 信息完整度:
  • 樣本:
  • 更新時(shí)間:2024-10-03 11:37:31
  • 瀏覽次數(shù):2
收藏
舉報(bào)

聯(lián)系我時(shí),請告知來自 興旺寶

珠海康寶萊儀表有限公司

其他

  • 經(jīng)營模式:其他
  • 商鋪產(chǎn)品:1981條
  • 所在地區(qū):
  • 注冊時(shí)間:2014-08-14
  • 最近登錄:2023-11-10
  • 聯(lián)系人:
產(chǎn)品簡介

Index:WMGBMPI525 Possible measurementsShort-circuit loop measurement:- impedance measurement with 23A current (44A phase-to-phase) - short-circuit resistor R=10,- measurement range: 95...440V, fr

詳情介紹
Index:WMGBMPI525
 
Possible measurements
 
  • Short-circuit loop measurement:
    - impedance measurement with 23A current (44A phase-to-phase) - short-circuit resistor R=10,
    - measurement range: 95...440V, frequency 45...65Hz,
  • Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30mA):
    - automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,
    - additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.
  • Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000mA. (Type AC, A and B).
  • Measurement of insulation resistance:
    - with test voltage 250V, 500V, 1000V, 2500V,
    - measurement range up to 10G,
    - automatic discharging after measurement,
    - automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,
    - acoustic signals in 5sec intervals for insulation resistance characteristic,
    - safety measurement - protection against overvoltage.
  • Measurement of earthing resistance.
  • Bi-directional testing of PE wire continuity using 200mA current.
    - Autocalibration of test leads.
  • Phase sequence testing.
  • Memory is divided into 10 memory banks each of them containing 99 memory cells.
  • Battery charge indicator.
  • AUTO-OFF function.
  • USB interface.
MPI-525 Technical Specifications
 
Possible measurements
  • Short-circuit loop measurement:
    -impedance measurement with 23A current (44A phase-to-phase) - short-circuit resistor  R=10Ω,
    - measurement range: 95...440V, frequency 45...65Hz,
  • Short-circuit loop measurement with resolution  0,01Ω, in distribution network without tiggering RCD (IΔn≥30mA):
    - automatic  calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,
    - additional UNI-Schuko plug for automatic measurement,  AGT adapter for 3 phase network measurement.
  • Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000mA. (Type AC, A and B).
  • Measurement of insulation resistance:
    - with test voltage 250V, 500V, 1000V, 2500V,
    - measurement range up to 10GΩ,
    - automatic discharging after measurement,
    - automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,
    - acoustic signals in 5sec intervals for insulation resistance characteristic,
    - safety measurement - protection against overvoltage.
  • Measurement of earthing resistance.
  • Bi-directional testing of PE wire continuity using 200mA current.
    - Autocalibration of test leads.
  • Phase sequence testing.
  • Memory is divided into 10 memory banks each of them containing 99 memory cells.
  • Battery charge indicator.
  • AUTO-OFF function.
  • USB interface.

Rated operational conditions:
- operation temperature     0...+50°C

Electric security:
- type of insulation: double, according to  PN-EN 61010-1and IEC 61557, EMC
- measurement category: IV 300V acc. to PN-EN 61010-1
- protection class acc. to  PN-EN 60529: IP54

Short-circuit loop impedance measurement  ZL-PE, ZL-N, ZL-L
Measurement using 23/40A current measurement range in accordance with
IEC 61557: 0,13...1999,9Ω
(for 1,2m lead):

Range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(5% m.v + 3 dgt)
20,0...199,9Ω 0,1Ω
200...1999Ω

rated voltage: 95...270V (forZL-PE i ZL-N) and 95...440V (for ZL-L)
frequency: 45...65Hz

Short-circuit loop impedance measurement ZL-PE RCD        
Measurement using 15mA current measurement range in accordance with
IEC 61557: 0,50...1999,9Ω

Range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(6% m.v. + 10 dgt)
20,0...199,9Ω 0,1Ω ±(6% m.v + 5 dgt)
200...1999Ω

rated voltage: 95...270V
frequency: 45...65Hz

Measurement of earthing RE
Rated voltage in accordance with IEC 61557-5: 0,5...1999Ω

Range Resolution Accuracy
0,00...9,99Ω 0,01Ω ±(2% m.v. + 4 dgt)
10,0...99,9Ω 0,1Ω ±(2% m.v. + 3 dgt)
100...999Ω
1,00...1,99kΩ 0,01kΩ

Insulation resistance measurement
Measurement range in accordance with IEC 61557-2:
- for UN = 50V: 50kΩ...250MΩ
- for UN = 100V: 100kΩ...500MΩ
- for UN = 250V: 250kΩ...1GΩ
- for UN = 500V: 500kΩ...2GΩ
- for UN = 1000V: 1MΩ...3GΩ
- for UN = 2500V: 2,5MΩ...9,99GΩ

Range*) Resolution Accuracy
0...1999kΩ 1kΩ
±(3% m.v. + 8 dgt)
2,00...19,99MΩ 0,01MΩ
20,0...199,9MΩ 0,1MΩ
200...999MΩ 1MΩ
1,00...3,00GΩ 0,01GΩ ±(4% m.v. + 6 dgt)
 1,00...9,99GΩ  0,1GΩ

*)   limited to measurement range.
- with UNI-Schuko additional error ±2%.

 

Phase sequence
- phase sequence indicator: forward, reverse
- mains voltage range UL-L: 100...440V (45…65Hz) UL-L: 100...440V (45...65Hz)
- display of phase-to-phase voltages

Low voltage test of the circuit and insulation continuity
Test of PE wire continuity using a ±200mA current

Range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(2% m.v. + 3 dgt)
20,0...199,9Ω 0,1Ω
200...400Ω 1

- Voltage on open terminals: 4…9V
- Test current at  R<2Ω: min. 200mA at rated battery voltage
- Autocalibration of test leads
- Measurements for both polarizations of the current

RCD trigger and response time test tA (for tA mode)
Measurement ranges in accordance with IEC 61557: 0ms ... up to the upper bound of the displayed value

Breaker
Type
Test
Current
Multiplier
Measurement
Range
Resolution Accuracy
Standard 0,5*IΔn 0...300ms

1 ms



± (2% m.v + 2 dgt)

 

1*IΔn
2*IΔn 0...150ms
5*IΔn 0...40ms
Selective 0,5*IΔn 0...500ms
1*IΔn
2*IΔn 0...200ms
5*IΔn 0...150ms

Precision of the differential current: for 0,5*IΔn:-8...0% dla 1*IΔn, 2*IΔn, 5*IΔn: 0...8%

Measurement of the RCD triggering current (IA) for sine waveform testing current

Selected
Current
Range Resolution
 
Test
Current
Accuracy
10mA 3,3...10,0mA 0,1mA 0,3xIΔ..1,0xIΔ ± 5% IΔn
30mA 9,0...30,0mA
100mA 33...100mA 1mA
300mA 90...300mA
500mA 150...500mA
1000mA 330...1000mA 1mA
It is possible to start the measurement from the positive or negative half of the forced leaking current

Measurement of the RDC triggering current (IA ) for a unidirectional half period sine
waveform test current with a 6mA direct current offset

Selected
Current
Range Resolution Test
Current 
Accuracy
10mA 4...20,0mA 0,1mA 0,4xIΔn..2,0xIΔn ±10%IΔn
30mA 12,0...42,0mA 0,4xIΔn..1,4xIΔn
100mA 40,0...140mA 1mA
300mA 120...420mA
500mA 200...700mA

a measurement is possible for a positive or negative forced leakage current

Measurement of the RCD triggering current (IA ) for direct testing current

Selected
Current
Range Resolution
Test
Current 
Accuracy
10mA 4,0...20,0mA 0,1mA 0,4xIΔn..2,0xIΔn ±10%IΔn
30mA 12,0...60,0mA 1mA
100mA 40...200mA
300mA 120...600mA
500mA 200...1000mA

?a measurement is possible for a positive or negative forced leakage current

„m.v.” measured value.


 
上一篇: KT-160熱成像儀
下一篇: MPI-520多功能儀表電氣裝置
同類優(yōu)質(zhì)產(chǎn)品

在線詢價(jià)

X

已經(jīng)是會員?點(diǎn)擊這里 [登錄] 直接獲取聯(lián)系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
產(chǎn)品對比

對比框